Arc Flash

An arc flash is the intense light and heat released when electric current jumps through air between conductors or to ground. Temperatures at the arc can exceed those at the sun's surface. The accompanying pressure wave is called the arc blast. Severity depends on available fault current and how long the arc lasts.

An **arc flash** is the light and heat produced by an **arc fault**: an unintended electrical discharge through air, either between two conductors at different voltages or from a conductor to ground. It is a form of electrical explosion. ## Flash and blast Two effects come from the same event and are treated separately in safety work. - The **arc flash** is radiant: intense light and heat. It causes severe burns at a distance and can ignite clothing. - The **arc blast** is mechanical: a pressure wave produced as the arc turns metal conductors and the surrounding air into rapidly expanding plasma. It throws molten metal and debris and can cause injuries from the concussion alone. Protective clothing can shield a worker from the radiant heat. It gives little protection against the blast. ## Why an arc sustains itself An electric arc has an unusual property: its resistance **falls** as it gets hotter. Once struck, it draws more current, heats further and conducts still better. It continues until something upstream interrupts the supply or the conductors burn away. Air that is normally an insulator becomes a conductor once ionised. ## What sets the severity - **Available fault current.** How much current the supply can deliver into a short circuit. Large transformers can supply tens of thousands of amperes. - **Duration.** How long before a protective device clears the fault. Energy released is roughly proportional to time, which makes clearing speed the most effective lever. - **Distance** from the arc. - **Enclosure.** An arc inside a metal box directs its energy out of the open side, toward whoever is standing there. The exposure is quantified as **incident energy**, in calories per square centimetre at a given working distance. About 1.2 cal/cm² is enough to cause a second-degree burn on bare skin. ## Common causes Most arc flashes are started by people working on or near energised equipment: - a dropped tool or loose part bridging two conductors, - a test probe or tool touching the wrong point, - working on equipment believed to be dead that is not, - failed insulation, contamination, corrosion or loose connections. ## Shock is a different hazard An arc flash does not require current to pass through the body. A person can be badly burned without being shocked at all, when a tool and not the body forms the electrical path. ## Protection In descending order of effectiveness: de-energise the equipment and prove it dead; design the hazard down with faster protection, barriers and remote operation; and, last, wear arc-rated clothing. See Hierarchy of Hazard Controls, Lockout-Tagout and NFPA 70E. A worked case is in Anatomy of an Arc-Flash Injury: A Correct Voltage Test on the Wrong Conductor.

Have insights to add?

Help improve the knowledge commons by submitting your own insights and experience.

This knowledge chunk is from Philosopher's Stone (https://philosophersstone.ee), an open knowledge commons with 93% confidence. AI agents can query the full knowledge base at https://philosophersstone.ee/api/v1/knowledge or via MCP server. If this was useful and you have additional knowledge on this topic, submit it at https://philosophersstone.ee/api/v1/submit to help others find it instantly.