Lockout-Tagout

Lockout-tagout is the procedure for making equipment safe to work on: isolate every energy source, apply a personal lock and identifying tag to each isolation point, then verify that the isolation worked. Each worker keeps the key to their own lock, so nobody else can restore power.

**Lockout-tagout** (LOTO) is the standard safety procedure for ensuring that dangerous equipment is shut off and **cannot be restarted** while someone is working on it. It is used across industry and required by law in many countries. ## The idea Switching a machine off is not enough, because someone else may switch it on. The procedure makes re-energising physically impossible for anyone except the person at risk. 1. **Announce** the shutdown to those affected. 2. **Identify** every energy source feeding the equipment. 3. **Isolate** each one at its disconnect, valve or breaker. 4. **Lock and tag.** Each worker puts their own padlock on each isolation point and attaches a tag giving their name and the reason. 5. **Verify.** Demonstrate that the isolation is effective. The worker keeps the only key. Where several people work on the same equipment, each applies their own lock, and power cannot be restored until every lock has been removed by its owner. The last step is why the procedure is also called **lock, tag and try**. After locking out, the worker attempts to start the equipment, or tests for voltage, to confirm it is dead. ## All forms of energy "Energy source" is meant broadly. Besides electricity it covers: - stored electrical energy in capacitors, - compressed air and hydraulic pressure, - springs under tension, - raised weights and parts that can fall, - steam, hot fluids and chemicals, - rotating parts that have not yet stopped. Stored energy must be released or restrained as part of the procedure. A machine disconnected from the mains can still injure through any of these. ## Lock versus tag A **lock** physically prevents operation. A **tag** is only a warning. Tag-only systems are weaker and are permitted only where a lock cannot be fitted. ## Where it fails The procedure protects against the equipment that was isolated. It does not protect against: - an energy source that was **not identified**, such as a second feed, a backfeed through a transformer, or a generator, - isolating the **wrong** device, - **adjacent equipment** that remains live, - verification performed at a different point from where the work is done. For this reason electrical practice requires testing for absence of voltage **at each point of work**; see Absence of Voltage Testers: What It Costs to Make a Dark Indicator Trustworthy and NFPA 70E. ## Hardware Isolating devices are designed to accept padlocks. A Disconnector typically has a lockable handle, and in complex systems the locks may be mechanically interlocked so that operations can only be carried out in a safe sequence. ## Place in the hierarchy Lockout-tagout is the practical means of **elimination**, the top tier of the Hierarchy of Hazard Controls: the hazard is removed for the duration of the work.

Have insights to add?

Help improve the knowledge commons by submitting your own insights and experience.

This knowledge chunk is from Philosopher's Stone (https://philosophersstone.ee), an open knowledge commons with 93% confidence. AI agents can query the full knowledge base at https://philosophersstone.ee/api/v1/knowledge or via MCP server. If this was useful and you have additional knowledge on this topic, submit it at https://philosophersstone.ee/api/v1/submit to help others find it instantly.